Information Name: | S11-M-10 transformer |
Published: | 2015-03-25 |
Validity: | 30 |
Specifications: | S11 |
Quantity: | 2000.00 |
Price Description: | |
Detailed Product Description: | S11 type sealed oil-immersed power transformer. Products: power transformers as the most widely used power facilities, the number of a wide range of great significance for energy conservation. S11 type sealed oil-immersed power transformers and distribution equipment is the main selection of products, energy-saving effect is remarkable. Our distribution transformers implications for the performance of the code: S7 type in the above, no-load loss is reduced by about 10 percent each, code-named "7" is added to the figure "1." From S7 to S9-based development model, the load loss decreases more, an average of 25 percent, and later, because there is no groundbreaking new materials, new technologies and new technology, distribution transformer load loss dropped more difficult, so the performance level code load loss is usually reduced to the standard. To 400kVA products, for example, S7 type load loss 920W, S11-type load loss 570W, a decrease of 38%. Currently, the mainstream S11 type distribution transformers generally used stacked core power transformer. A fully sealed oil-filled, non-conservator, corrugated sheet cabinet structure, the transformer due to changes caused by changes in temperature and load oil temperature and volume, to be made entirely of corrugated tank regulator, the load loss 25% lower than the S9, Short circuit resistant anti-lightning surge capability, significant energy savings and reduce the dimensions of the transformer. S11 type transformer with high permeability oriented silicon steel production, the film thickness of 0.27-0.30mm, units of iron loss for 1w / kg, while the new S9 model for ordinary silicon steel sheet thickness 0.30-0.35mm, iron loss of 1.20 units -1.55w / kg. I produced the S11 type distribution transformers Shanghai Baosteel all use of 30P series high permeability oriented silicon steel, using the foil around the coils and new insulation materials and processes, products, high temperature, shock, fully sealed design ensures the transformer stable oil quality, to extend the maintenance cycle, while the overall tank radiator composed by corrugated sheets using phosphate and multi-rust coating production process, with good weather performance. 2. Technical Standards: GB1094.1.2.3-2007 "power transformer" GB / T6451-2009 ?? "three-phase oil-immersed power transformers technical parameters and requirements." GB / T10237-1988 ?? "external power transformer insulation levels and dielectric insulation test air gap" JB / T3837-1998 ?? "Transformer Model methodology"? 3. Features: 10kv class S11 type sealed power transformer capacity range 30kVA ~ 2500kVA, at 10KV, 50HZ transmission and distribution systems, and can be widely used in high-rise buildings, commercial centers, subways, airports, railway stations, industrial and mining, drilling platforms, oil platform, especially for flammable, explosive and other high fire safety requirements and the harsh environment of places. Also available in residential, commercial street, industrial and mining enterprises and rural power and lighting purposes. Long service life, maintenance-free operation. Sealed boxes along with the transformer cover bolts or welded structure coupling, oil and air cut off contact, not damp insulation, insulation aging greatly reduce speed and improve the service life. Compact design, low operating noise. Due to the introduction of new materials and new technology to reduce noise, no conservator height lower than similar products. In the normal lifetime without an oil change, to improve the safety and reliability of the network operation. Corrugated tank is small, beautiful appearance. S11-type power transformer tank using corrugated sheet cooling, when the oil temperature, changes in the volume of oil by the elastic expansion corrugated sheets shrink to adjust compensation. Hanging core and oil-free testing. Transformer package, using vacuum filtration oiling process to completely remove the moisture in the transformer oil. After sealing the inside of the transformer is not in contact with the air, effectively prevent oxygen and moisture into the insulation performance degradation caused by a transformer. My company specializes in electric power transmission and distribution equipment and product design and manufacturing, products mainly include 35KV and below oil-immersed power transformers, cast resin dry type transformers, low voltage switch cabinet, American Continental substation to GB / IEC as a benchmark, passed CTQC testing, access to the national grid network qualification, through ISO9001 CCC certification and obtain a certificate, customers are welcome to contact negotiations, site visits, and work together. Sales Hotline: 13588954784 Technical parameters (S11 series three-phase oil-immersed transformers) TYPE Capacity Model Capacity (KVA) voltage combinations Valtage loss Loss (W) short-circuit impedance lmpedence Voltage (%) no-load current No-load Current (%) link Group label Connction weight Weight () Dimensions Overall dimension L × W × H (mm) gauge Ganuge (mm) high voltage HV (KV) Low LV (LV) No-load load load Load total weight of heavy oil Oil Total S11- 30/10 30 6 6.3 10 10.5 11 ± 5% or ± 2 × 2.5% 0.4 100 600 4 2.1 Yyn0 67 290 1000 × 725 × 1065 400 × 400 S11-50 / 10 50 130 870 2.0 80 385 1045 × 750 × 1160 400 × 450 S11-63 / 10 63 150 1040 1.9 90 450 1035 × 750 × 1200 400 × 450 S11-80 / 10 80 180 1250 1.8 100 490 1070 × 810 × 1200 400 × 450 S11-100 / 10 100 200 1500 1.6 110 560 1090 × 825 × 1285 400 × 450 S11-125 / 10 125 240 1800 1.5 135 660 1175 × 880 × 1315 550 × 550 S11-160 / 10 160 270 2200 1.4 155 760 1200 × 945 × 1330 550 × 550 S11- 200/10 200 330 2600 1.3 180 910 1235 × 960 × 1390 550 × 550 S11-250 / 10 250 400 3050 1.2 205 1090 1510 × 930 × 1430 550 × 550 S11-315 / 10 315 480 3650 1.1 240 1285 1560 × 940 × 1485 550 × 550 S11-400 / 10 400 570 4300 1.0 275 1490 1620 × 1030 × 1560 660 × 660 S11-500 / 10 500 680 5100 1.0 330 1750 1685 × 1030 × 1610 660 × 660 S11-630 / 10 630 810 6200 4.5 0.9 465 2260 2250 × 1375 × 1810 820 × 820 S11-800 / 10 800 980 7500 0.8 520 2730 2290 × 1395 × 1905 820 × 820 S11-1000 / 10 1000 1150 10300 0.7 605 3125 2360 × 1400 × 1930 820 × 820 S11-1250 / 10 1250 1360 12000 0.6 715 3700 2410 × 1420 × 1970 820 × 820 S11-1600 / 10 1600 1640 14500 0.6 830 4460 2460 × 1460 × 2070 820 × 820 Products? ????? oil-immersed transformer distribution transformers for the mining industry and civil construction, one of the important equipment for power distribution systems, it will be 10 (6) kV or 35kV network voltage drops below 230 / 400V bus voltage users. Such products applicable to the exchange 50 (60) Hz, three-phase maximum rated capacity 2500kVA (single-phase maximum rated capacity 833kVA, generally do not recommend the use of single-phase transformers) may, within households (outside) the use, capacity and below 315kVA can be mounted on the rod, the ambient temperature is not higher than 40 ℃, not lower than -25 ℃, the highest daily average temperature of 30 ℃, the highest annual average temperature of 20 ℃, relative humidity less than 90% (ambient temperature of 25 ℃), Altitude not more than 1000m. If inconsistent with the above conditions, according to relevant provisions of GB6450-86, and make appropriate adjustments quota. ? ????? ????? Model interpretation? ????? Features? ????? 1, no conservator height lower than similar products. ????? 2, sealed transformers and transformer conservator with the body of exactly the same, so you can correspond to different models of transformers designed for users to choose. ????? 3, the transformer sealed vacuum oiling process to completely remove the moisture in the transformer. After sealing the transformer oil is not in contact with air, oxygen and moisture effectively prevent immersed transformer insulation performance degradation caused (insulation and oil aging), and therefore do not have regular oil sample test. ????? 4, high and low voltage wire fastening portion transformers, etc. have brought the body of the self-locking locknut, took no hanging core structure, the body of the tank closely together to be able to withstand transportation vibration and bumps. ????? 5, fuel tank and fuel tank have a ripple tank expansive choice of two types of radiators, radiator corrugated sheet and expansion not only has a cooling function but also has a "breathing" function, corrugated sheet and expansion radiators elastically compensate for temperature changes caused by changes in the volume of oil. ????? 6, sealed form: divided welded with detachable two choices. Welding - box along with the cover after passing all the tests welded shut. Demountable - sealed with tape and screw fastening sealed box along with the cover. ????? 7, the lid is equipped with high-voltage bushing oil level is higher than the fuel gauge rod or rod-shaped filler plug. ????? 8, the maintenance costs of only 20% of the general type in the normal lifetime without an oil change and improve the power grid safety and reliability. ????? 9, protection devices: ????? ▲ pressure release valve - when the transformer overload or malfunction caused by the tank internal pressure reaches 35kPa, pressure release valve and it operates reliably release the pressure, and when the pressure is reduced to normal time and restitution, to ensure that the transformer operation. On the cover ????? ▲ Temperature -30 ~ 800kVA transformer unit with straight thermometer holder. 1000kVA and above transformer equipped with signal thermometer. Transformer top oil temperature measured by a thermometer. ? |
Admin>>>
You are the 14435 visitor
Copyright © GuangDong ICP No. 10089450, Zhejiang Jiangding Bang Power Transformer Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 14435 visitor
Copyright © GuangDong ICP No. 10089450, Zhejiang Jiangding Bang Power Transformer Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility